Benefits
- No nozzles means no potential of clogging
- This range of humidifiers is manufactured from high impact polypropylene and will NOT corrode
- Includes integral motor
- Available in 240V or 415V
- Weatherproof – rated IP55
- Includes adjustable water flow
- Low operating costs and low maintenance
- All U-SERIES humidification systems can be connected to a Timer
https://coldmistcooling.com.au/solutions/humidification/u-series-professional-humidifiers#sigProId5f8b426856
U-SERIES range of Water Atomisers:
Coldmist Fresh Climate UCP
![]()
|
Features |
UCP 1 |
UCP3 |
|
|
Atomisation Capacity |
L/m |
0.5 |
0.5 |
|
|
Weight |
Kg |
7 |
7 |
|
|
Power Supply Data |
Single Phase |
Three Phase |
||
|
Frequency |
Hz |
50 |
50 |
|
|
Main Motor Power |
W |
300 |
300 |
|
|
Main Motor Current |
A |
1.4 |
0.5 |
|
|
Main Motor Voltage |
V |
230 |
400 |
|
|
Pump Motor Power |
W |
14 |
14 |
|
|
Pump Motor Current |
A |
0.06 |
0.06 |
|
|
Pump Motor Voltage |
W |
230 |
230 |
Coldmist Fresh Climate - UCP-fly
|
Features |
UCP Fly H15 |
UCP Fly H20 |
UCP FLY H25 |
|
|
Atomisation Capacity |
L/m |
0.25 to 0.5 |
0.25 to 0.5 |
0.25 to 0.5 |
|
|
Weight |
Kg |
13 |
13 |
13 |
|
|
Power Supply Data |
Single Phase |
Single Phase |
Single Phase |
||
|
Frequency |
Hz |
50 |
50 |
50 |
|
|
Main Motor Power |
W |
380 |
390 |
420 |
|
|
Main Motor Current |
A |
1.8 |
1.9 |
2.05 |
|
|
Main Motor Voltage |
V |
230 |
230 |
230 |
|
|
Air Flow |
m³/Hr |
750 |
1100 |
1800 |
Coldmist Fresh Climate - UX56
|
Features |
UX56-T1 |
UX56-M |
UX71-TT |
UX71-TS |
|
|
Atomisation Capacity |
L/m |
0.25-0.7 |
0.25-0.7 |
0.25-0.7 |
0.25-0.7 |
|
|
Air Flow |
m³/Hr |
6700 |
6600 |
11000 |
14500 |
|
|
Weight |
Kg |
28 |
28 |
48 |
48 |
|
|
Power Supply Data |
Three Phase |
Single Phase |
Three Phase |
Three Phase |
||
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
|
|
Main Motor Power |
W |
420 |
390 |
690 |
1100 |
|
|
Main Motor Current |
A |
1.05 |
2.0 |
1.4 |
1.4 |
|
|
Main Motor Voltage |
V |
400 |
230 |
400 |
400 |
|
|
Atomiser Motor Power |
W |
300 |
300 |
300 |
300 |
|
|
Atomiser Motor Current |
A |
0.5 |
1.4 |
0.5 |
0.5 |
|
|
Atomiser Motor Voltage |
V |
400 |
230 |
400 |
400 |
|
|
Overall Length |
mm |
800 |
800 |
1060 |
1060 |
|
|
Main Body Diameter |
mm |
564 |
564 |
715 |
715 |
|
|
Overall Height |
mm |
624 |
624 |
775 |
775 |
|
|
Speed |
rpm |
890 |
865 |
670 |
900 |
|
|
Noise Level |
dB |
75 |
75 |
73 |
82 |
Coldmist Fresh Climate - UX71
|
Features |
UX56-T1 |
UX56-M |
UX71-TT |
UX71-TS |
|
|
Atomisation Capacity |
L/m |
0.25-0.7 |
0.25-0.7 |
0.25-0.7 |
0.25-0.7 |
|
|
Air Flow |
m³/Hr |
6700 |
6600 |
11000 |
14500 |
|
|
Weight |
Kg |
28 |
28 |
48 |
48 |
|
|
Power Supply Data |
Three Phase |
Single Phase |
Three Phase |
Three Phase |
||
|
Frequency |
Hz |
50 |
50 |
50 |
50 |
|
|
Main Motor Power |
W |
420 |
390 |
690 |
1100 |
|
|
Main Motor Current |
A |
1.05 |
2.0 |
1.4 |
1.4 |
|
|
Main Motor Voltage |
V |
400 |
230 |
400 |
400 |
|
|
Atomiser Motor Power |
W |
300 |
300 |
300 |
300 |
|
|
Atomiser Motor Current |
A |
0.5 |
1.4 |
0.5 |
0.5 |
|
|
Atomiser Motor Voltage |
V |
400 |
230 |
400 |
400 |
|
|
Overall Length |
mm |
800 |
800 |
1060 |
1060 |
|
|
Main Body Diameter |
mm |
564 |
564 |
715 |
715 |
|
|
Overall Height |
mm |
624 |
624 |
775 |
775 |
|
|
Speed |
rpm |
890 |
865 |
670 |
900 |
|
|
Noise Level |
dB |
75 |
75 |
73 |
82 |
Coldmist Fresh Climate PH-C Humidifier
|
Features |
PH |
PH-R |
|
|
Atomisation Capacity |
L/m |
Up to 0.05 |
Up to 0.125 |
|
|
Weight |
Kg |
11 |
11 |
|
|
Power Supply Data |
Single Phase |
Single Phase |
||
|
Frequency |
Hz |
50 |
50 |
|
|
Pump Motor Power |
W |
14 |
14 |
|
|
Pump Motor Current |
A |
0.06 |
0.06 |
|
|
Pump Motor Voltage |
V |
400 |
230 |
|
|
Atomiser Motor Power |
W |
250 |
250 |
|
|
Atomiser Motor Current |
A |
1.8 |
1.8 |
|
|
Atomiser Motor Voltage |
V |
230 |
230 |
|
|
Dimensions LxDxH |
mm |
420x400x507 |
420x400x507 |
|
|
IP Rating |
56 |
5 |
Coldmist Fresh Climate - ESUX
|
|
Features |
ESUX141R |
ESUX121R |
ESUX101R |
|
|
Atomisation Capacity |
L/m |
0.25-0.7 |
0.25-0.7 |
0.25-0.7 |
|
|
Air Flow |
m³/Hr |
34600 |
21370 |
15350 |
|
|
Power Supply Data |
Single Phase |
Single Phase |
Single Phase |
||
|
Frequency |
Hz |
50 |
50 |
50 |
|
|
Fan Motor Power |
W |
750 |
550 |
370 |
|
|
Fan Motor Current |
A |
1.05 |
2.0 |
1.4 |
|
|
Fan Motor Voltage |
V |
400 |
230 |
400 |
|
|
Atomiser Motor Power |
W |
290 |
290 |
290 |
|
|
Atomiser Motor Current |
A |
0.5 |
1.4 |
0.5 |
|
|
Atomiser Motor Voltage |
V |
230 |
230 |
230 |
|
|
Dimensions |
mm |
1378x1378x360 |
1075x1075x360 |
925x925x360 |
|
|
Fan Diameter |
mm |
1270 |
990 |
780 |








Professional growers know that it is vital to monitor and control all environmental factors that can affect their crops. Critical
In wine storage applications, increasing the relative humidity can dramatically reduce the evaporation of wine through the oak barrels. It
As paper products can readily gain and lose moisture, a constantly controlled humidity level is critical to consistent and improved
Maintaining the Equilibrium Moisture Content (EMC) in the woodworking industry is a KEY factor to improving both the quality and
A critical part of the process in textile production is properly maintained humidity levels, usually between 50% and 65% - this
Benefits of Humidifiers in the tobacco curing process - Aquafog HRSM mobile fogging systems are excellent, efficient humidifiers. These units will